Standard Buildings
Standard features:
Blast Criteria
- 5 and 8 psi (freefield overpressure)
- 200 ms (duration)
- Medium damage (ASCE damage criteria)
- 12’ x 40’ and 14’ x 40’
Electrical
- 220/120VAC Single Phase main Panel
- 150A main breaker
- 120V/20amp duplex receptacles
- MC Cable with ground
- Penetrations
- 2 – ¾”
- 2 – 1-1/2”
- 2 – 2”
- Ground lug posts
- 4’ fluorescent lay-in fixtures
- Three way light switches
- Emergency LED egress lighting with two directional beams
- Class 1 Div 2 exterior lighting
Communication
- CAT5e cabling
- RJ45 comm/data jacks
HVAC
- Class 1 Div 2 wall mount with aux heat, 120/240V Single Phase – Dual CSA & UL certified
- Wall mounted thermostats
Exterior Doors
- 3’0” x 7’0” blast rated doors
- Equal to or greater than building blast requirements
- Universal door closer
- Yale mortise lock with lever set hardware
Insulation Specifications
- Spray Polyurethane Foam (SPF) Thermal Insulation
- R30 on ceilings (R40 - optional)
- R25 on walls and floors
Interior
- Metal stud and track framing
- Vinyl coated Drywall with batten strip, Hampton Grey
- Vinyl cove base, Blue Grey
- Acoustical ceiling
- Tongue & groove dry ply sub floor
- injection molded, homogeneous, solid vinyl interlocking tile floor
- 3’0” x 7’0” solid core doors with jamb and locksets
Exterior Finish
- Sand blasted to near white finish
- paint system that meets C5-I standard for highly corrosive environments in accordance with ISO standards
Lifting
- lifting lugs on each corner for equal COG
- safety lugs on roof
Optional Features:
NFPA 496 compliance
|